ACI 117-10 Specification for Tolerances for Concrete Construction and Materials and Commentary provides standard tolerances for concrete construction and materials. This document is intended to be used by specification writers and ACI committees writing standards as the reference document for establishing tolerances for concrete construction and materials.
Contents:
- Introduction
- Section 1
- General requirements; Scope; Requirements; Definitions; Referenced standards
- Section 2 | Materials
- Reinforcing steel fabrication and assembly; Reinforcement location; Placement of embedded items, excluding dowels in slabs-on-ground; Concrete batching; Concrete properties
- Section 3 | Foundations
- Deviation from plumb; Deviation from location; Deviation from elevation; Deviation from plane; Deviation from cross-sectional dimensions of foundations
- Section 4 | Cast-in-place concrete for buildings
- Deviation from plumb; Deviation from location; Not used; Deviation from elevation; Deviation from cross-sectional dimensions; Deviation from formed opening width or height; Deviation from relative elevations or widths for stairs; Deviation from slope or plane; Sawcut depth in slab-on-ground
- Section 5 | Cast-in-place concrete at interface with precast concrete (except tilt-up concrete)
- Deviation from elevation—cast-in-place concrete; Deviation from location—cast-in-place concrete; Deviation from dimension—cast-in-place concrete; Deviation from plane at bearing surface—cast-inplace concrete measured over length or width of bearing surface
- Section 6 | Masonry
- Section 7 | Cast-in-place, vertically slipformed building elements
- Deviation from plumb for buildings and cores; Horizontal deviation; Cross-sectional dimensions; Openings through elements; Embedded plates; Deviation from plumb for slipformed and jumpformed silos
- Section 8 | Mass concrete
- Deviation from plumb; Horizontal deviation; Vertical deviation; Cross-sectional dimension; Deviation from plane
- Section 9 | Canal lining
- Horizontal deviation; Vertical deviation; Cross-sectional dimensions
- Section 10 | Monolithic water-conveying tunnels, siphons, conduits and spillways
- Horizontal deviation; Vertical deviation; Cross-sectional dimensions; Deviation from plane
- Section 11 | Cast-in-place bridges
- Deviation from plumb; Horizontal deviation; Vertical deviation; Length, width, or depth of specified elements; Deviation from plane; Deck reinforcement cover; Bearing pads
- Section 12 | Exterior pavements and sidewalks
- Horizontal deviation; Vertical deviation of surface
- Section 13 | Chimneys and cooling towers
- Deviation from plumb; Outside shell diameter; Wall thickness
- Section 14 | Cast-in-place nonreinforced pipe
- Wall thickness; Pipe diameter; Offsets; Surface indentations; Grade and alignment; Concrete slump
- Section 15 | Tilt-up concrete
- Panel forming; Deviation from plumb; Deviation from elevation; Deviation from location; Deviation from slope or plane; Deviation from relative widths
- Notes to Specifier
- General notes
- Foreword to checklists
- Mandatory Requirements Checklist
- Optional Requirements Checklist